Industrial Emergency Lighting Units, IND Series, Damp Location, Cold Weather |
for Krypton, Halogen and Incandescent Lamps, UL, ULT, NFPA, NEC, OSHA |
|
|
|
Intended Use |
• | Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. |
|
• | Unique, innovative design for a variety of light and heavy industrial applications and heavy commercial environments. |
|
• | Superiorperformance lamp heads are ideally suited for higher mounting heights. |
|
• | Perfect for pole and column mounting. |
|
|
Construction |
• | Rugged, 0.140" thick, injection-molded thermoplastic. |
|
• | Vertical orientation is designed especially for pole or column mounting. |
|
• | Also suitable for wall and I-beam mounting. |
|
• | Ceiling and pendant mounting, with accessory equipment, available on selected models. |
|
• | Easy-mount installation with one galvanized, 12-gauge steel mounting bracket shipped standard. |
|
• | Conduit entry points are located on top and both sides of the unit. |
|
• | Maintenance is made easy by tool-less re-lamp, single tool entry, hinging front cover, printed circuit board mounting shelf and battery belt. |
|
• | Non sealed-beam lamps feature unique field-adjustable beam spread. |
|
• | Sealed maintenance-free, lead-calcium battery with wattage capacities from 18-450W for 90 minutes of emergency operation. |
|
• | Available in 6V, 12V and 24V. |
|
• | Dual voltage input capability (120/277V). |
|
|
Listings |
|
|
|
• | Cold weather (ULT) listing. |
|
• | NFPA 101 illumination standards. |
|
• | NEC illumination standards. |
|
• | OSHA illumination standards. |
|
|
|
Series IND Emergency Units |
|
|
Options (add suffix to Configuration number) and NotesLearn More… |
|
Suffix |
Description |
Note(s) |
(blank) |
Damp location 50° to 103°F (10° to 40°C); except IND6100 and IND24450, which are listed 60°to 90°F (15° - 32°C) |
|
XTRA |
Extra package features remote test, time delay and damp location 50° to 104° (10° to 40°C) |
2 |
SEL |
Select package features self diagnostics, time delay, audible failure indication and damp location 50° to 104°F (10° to 40°C) |
|
PREM |
Premium package features high-temperature ni-cad battery (IND618 and IND1236 only) or high-ambient lead-calcium battery (IND12100 only), self diagnostics, time delay, audible failure indication and damp location; UL Listed for 32° to 131°F (0° to 55°C) |
3, 4 |
ULT |
Ultimate package features heater, thermostat, battery blanket with hightemperature ni-cad battery (IND618 and IND1236 only) or high-ambient leadcalcium battery (IND12100 only), self diagnostics, time delay, audible failure indication and damp location |
4, 5 |
|
|
Notes: |
• | 1: All models provided with two lamp heads. |
|
• | 2: Must order a remote transmitter (ELA RTT). One per job required. |
|
• | 3: Only available on IND618, IND1236 and IND12100. |
|
• | 4: IND12100 PREM and IND12100 ULT come in a larger housing size. |
|
• | 5: UL Listed for -40° to 55° C (-40° to 131°F). |
|
• | 6: Add 0.3 amps, 31watts for models with ULT option. |
|
• | 7: ELA IND PM accessory cannot be used with the IND 12100 PREM or IND12100 ULT. |
|
|
|
|
|
|
|
|
Active Catalog Numbers within this Product group |
Catalog No. |
Description |
|
Stock |
|
Replacement battery, Lead Calcium, 6V, 12Ah (includes 4) for use with IND12100 |
|
|
|
Select desired product above to get further informations. Non stock products have a minimum order quantity. |
|
|
|
|
|
|
|
Catalog No. | Description |
ELA-RTT | Remote Test Transmitter, Type: ELA RTT |
ELA-WG2M | Wireguard, small (18W-100W), Type: ELA WG2M |
ELA-WGLG | Wireguard, large (150-450W), Type: ELA WGLG |
ELA-BS | Banding Strap, Type: ELA BS |
ELA-IND-PM | Pendant Mount Kit for IND618/654/6100/1236/1254/12100/241006, Type: ELA IND PM |
ELA-IND-CM1 | Ceiling Mount Kit for IND6183, Type: ELA IND CM1 |
ELA-IND-CM2 | Ceiling Mount Kit for IND654/1236/12543, Type: ELA IND CM2 |
ELA-IND-CM3 | Ceiling Mount Kit for IND61003, Type: ELA IND CM3 |
ELA-IND-R3 | Pre-Pack to install third Head, Type: ELA IND R3 |
|
|
|
|
|
|
|
|
|
|
| Selection of further Products |
Product image |
Product group and Description |
|
|
Emergency Lighting Units, Series INDX, 6V, 12V, 24V, 90min. Emergency Operation, 0°C to 55°C, NEMA 4/4X, IP66, UL, NFPA 70-NEC, OSHA, NSF |
|
|
Industrial Steel Emergency Lighting Units, 120Vac/277Vac, min. 90 Minutes Illumination, UL listed. Meets UL 924, NFPA 101, NEC and OSHA illumination standards |
|
|
Die-Cast Architectural Emergency Light Unit Model AFN, 120/277V, 90 Min. Illumionation, UL, Wet location (EXT) listed. Damp location (PREM, EXT) listed. Cold weather (EXT) listed, meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards |
|
|
Emergency Lighting Units Series ELM6 & ELM12, 6V or 12V, for Krypton or Halogen Lamps, UL, Damp Location 50°F-104°F (10°-40°C) listing available, meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards |
|
|
Emergency Lighting, Square Series ELSQ/ELSQM, Surface/recessed Mounting, meets UL924, NFPA 101, NEC and OSHA illumination standards |
|
|
Rough Service Utilitarian Lights, Vandal-Resistant, for Incandescent or Compact Fluorescent (twin-tube) Lamps, Wall or Ceiling Mount, Wet Location |
|
|
Emergency Industrial Fluorescent Fixtures, 90 Minutes, Series DMW |
|
|
Select desired product group above to get further informations. |
|
|
|
|
|
|
|
|
Specifications and information are nominal and are subject to change without notice.