USA, Canada |
|
Catalog No: GMDGT-0.5-D shown |
|
Transformer Disconnect, GMDGT Series |
Compact Transformer Disconnect (0.5 kVA to 1 kVA), Enclosure NEMA 1 (IP22) |
|
The GMDGT Series is suitable for use on circuits capable of delivering up to 200kA RMS symmetrical short circuit current to meet the most stringent Canadian and UL 508A requirements. This NEMA 1 (IP22) enclosed series features a small footprint for applications where back plate space is at a premium. |
|
|
Features |
|
• | 200 kA RMS short circuit current rating |
|
• | Lockable switch in the off position with primary integral Class CC fuses |
|
• | Secondary fuseholders only – suitable for Ø 13/32" x 1 1/2" fuses (Ø 10.3 x 38.1)mm |
|
• | Electrostatically shielded transformers |
|
|
• | Optional 15 Amp receptacle |
|
|
|
|
|
|
|
|
Product Selection |
Transformer kVA Rating |
Model Catalog No. |
Replaces Older Model Catalog No. |
Input (primary) |
Output (secondary) |
Primary Fuse (F1 and F2) |
Maximum Secondary Amps (F3 and F4) |
Receptacle |
Approx Weight lb (kg) |
Base units |
0.5 kVA |
|
GMDGTB-07 |
480V, 1PH, 60Hz |
120V, 60Hz |
3A |
6A |
no |
31 (14) |
0.5 kVA |
|
GMDGTA-07 |
480V, 1PH, 60Hz |
120V, 60Hz |
3A |
6A |
NEMA 5-15R duplex |
31 (14) |
1.0 kVA |
GMDGT-1 |
GMDGTB-05 |
480V, 1PH, 60Hz |
120V, 60Hz |
6A |
12A |
no |
39 (18) |
1.0 kVA |
|
GMDGTA-05 |
480V, 1PH, 60Hz |
120V, 60Hz |
6A |
12A |
NEMA 5-15R duplex |
39 (18) |
|
|
|
|
|
|
|
|
|
Special configurations |
0.5 kVA |
GMDGT-0.5-M-432* |
GMDGTA-07-BZ967 |
480/380V, 1PH, 50Hz |
220V, 50Hz |
3A |
2.27A |
European "SCHUKO" |
37 (17) |
1.0 kVA |
|
GMDGTA-05-BZ967 |
480/380V, 1PH, 50Hz |
220V, 50Hz |
5A |
4.55A |
European "SCHUKO" |
44 (20) |
Further special configurations available on request only, see "Options Available for Transformer Disconnects". |
|
Catalog numbers in bold indicates active products in this group. Contact our sales office for the others. |
Note: Secondary fuses are not provided. * Indicate with order if c(UL)us label is required. |
|
|
|
Circuit Diagrams and Dimensions, Optional Fuses, Options Available |
• |
|
|
Specifications and information are nominal and are subject to change without notice. |
|
|
• |
|
|
Specifications and information are nominal and are subject to change without notice. |
|
|
• |
|
|
| Optional Fuses (must be ordered separately) |
Product image |
Catalog No. and Description |
|
Stock |
|
Class CC Time-Delay Fuse Link, Type KLDR 2A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
18 |
|
Class CC Time-Delay Fuse Link, Type KLDR 3A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
36 |
|
Class CC Time-Delay Fuse Link, Type KLDR 4A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
16 |
|
Class CC Time-Delay Fuse Link, Type KLDR 5A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
33 |
|
Class CC Time-Delay Fuse Link, Type KLDR 6A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
24 |
|
Class CC Time-Delay Fuse Link, Type KLDR 12A 600V AC, Recommended for Inductive Loads (e.g. Control Transformers, Solenoids, and Similar), UL/CSA, Dimensions (L 38.1 x Ø 10.3)mm |
|
38 |
|
Select desired product above to get further informations. Non stock products have a minimum order quantity. |
|
|
|
• |
|
Specifications and information are nominal and are subject to change without notice.